Before simulating, the engine checks that each string is compatible with the inverter under the extreme conditions of the location. These are the usual design checks for a PV array.

Checks

# Rule Worst case
1 String Voc at cold temperature ≤ maximum DC voltage of the inverter Cold: the voltage rises
2 String Vmp at hot temperature ≥ minimum MPPT voltage Heat: the voltage drops
3 String Vmp at cold temperature ≤ maximum MPPT voltage Cold
4 Current of the parallel strings (Imp) ≤ 1.10 × maximum MPPT current –
5 Isc of the parallel strings ≤ 1.4 × maximum MPPT current –
6 Number of inputs used ≤ inverter MPPTs –
7 DC/AC ratio ≤ maximum (1.4 by default) –

Design temperatures

Temperature Default Use
Cold design temperature −10 °C Maximum Voc and Vmp
Hot design temperature 70 °C Minimum Vmp

Both can be configured in Advanced settings. You can ask for the cold temperature to be calculated automatically from the local climate (yearly minimum with a margin).

How the voltages are calculated

  • Voc at temperature T: Voc · N_series · (1 + β_Voc · (T − 25 °C)), where β_Voc is the module's Voc temperature coefficient.
  • Vmp at temperature T: Vmp · N_series · (1 + γ · (T − 25 °C)). The Vmp coefficient is not in datasheets, so it is approximated with the Pmax one (Vmp ≈ Pmax/Imp and the current barely changes with temperature); it is the most unfavourable criterion at hot temperature.

Messages

If something does not comply, the application shows the reason with the specific values, for example:

  • «String Voc at −10 °C (812 V) > inverter Vmax (800 V)»
  • «String Vmp at 70 °C (148 V) < Vmppt_min (160 V)»
  • «Combined Imp (20.4 A) > MPPT Imax (16.0 A)»

Maximum and minimum number of modules

The engine also calculates:

  • the maximum number of modules in series (from cold Voc and from cold Vmp against the MPPT maximum),
  • the minimum (from hot Vmp),
  • the maximum number of parallel strings per MPPT (from current),
  • the maximum total number of modules from the DC/AC ratio.

This is pre-design

The validation uses datasheet data and design temperatures. It does not replace the final check with the manufacturer's specifications and the construction project.