A simulation result is only as good as its validation. This page explains what has been checked, against what, and what remains to be done, without embellishment.

How it is validated

Each block of the calculation is checked against an independent reference (the pvlib library, a closed-form formula or a hand-worked solution) and, for the complete engine, against physical and accounting invariants in combination matrices. The automated test suite runs on every change.

Coverage by block

Block Reference or criterion Result
Hay-Davies transposition pvlib, 6 orientations Difference < 1 %
Plane geometry With tilt 0, POA = GHI Correct
Cell temperature (Faiman) Closed-form formula and pvlib Correct
Martin-Ruiz IAM pvlib, 3 soiling levels Difference < 0.01 (direct) and < 0.03 (diffuse)
Linear thermal loss γ·(T − 25) Correct
Spectral effect Bounded range; precipitable water by site and hemisphere Correct
Model combinations 7 transpositions × 2 IAM × 2 PV models = 28 runs Invariants met, spread < 8 %
Optimal orientation Independent fine sweep, 3 latitudes, both hemispheres Correct
Consumption 8 curves × 3 time zones × 3 consumptions: sum = annual consumption Correct
Balance without battery Hand-worked case Correct
Balance with battery Energy conservation, charge limits, no simultaneous charge and discharge Correct
Off-grid balance No grid or export, energy closure Correct
Economics Cases recalculated by hand Correct
Inverter PVWatts formula by hand and pvlib Correct
Shading Fast model against the full I-V circuit Mean error ≈ 1 point
Complete engine Site × type × tariff matrix; plausible specific yield Passes

Comparison with PVsyst

With a 445 W module (Jinko JKM445N, PVsyst parameters) in three cases in Cordovilla (Navarre), the annual DC energy of Radiaris is within +0.10 %, +0.16 % and +0.26 % of PVsyst. The IAM coefficients and the single-diode model follow the PVsyst parameterisation.

Findings corrected during validation

  • Spectral effect: it used a Spanish precipitable water table for the whole world (in the southern hemisphere it inverted the seasons). It is now calculated per site. Effect on energy < 1 %.
  • Economics: the inverter and battery replacement costs did not include VAT, although CAPEX did. It underestimated those costs by 21 % in NPV, IRR, payback and LCOE. Corrected.

Accepted conventions

  • Initial battery state of charge at 50 %: it contributes half a bank of energy once (≈ 0.1 % of the annual energy).
  • The Martin-Ruiz table uses the C2 from the PVsyst data sheet; it differs from the pvlib formula by < 0.01 in diffuse IAM.
  • Default prices and costs are indicative.

Not yet validated

  • Experimental validation with measured production from real installations: in progress. Until then, use the uncertainty and the comparison with real production in your own projects.
  • Shading: validated against the I-V circuit, not against measurements.

Model limits

Limit Consequence
Typical weather year A real year can deviate; see P50/P90/P99
Hourly time step It does not capture minute-scale variations (on irradiance and clipping)
Fixed modules No trackers
Spanish simplified compensation Outside Spain the export regime has to be validated
Average prices in indexed tariffs It does not use real hourly prices
Battery strategies Self-consumption and backup; no charging from the grid or by tariff
Subsidies and deductions Informative only in the offer
Weekday/holiday consumption Only with your own curve

How to report a bug

Write to hola@radiaris.com with the project, what you expected and what you see. A reproducible case helps us a lot.